Description
Split heat pumps market Germany: sales in thousand units and forecast to 2031
How is the split heat pumps market in Germany developing? The dataset quantifies domestic sales of air-to-water heat pumps of split design in thousand units for every quarter from Q1/2021 to Q4/2031 – as historical market data and forecast.
A split system, well suited to heating and cooling, divides the refrigerant circuit: compressor and evaporator sit outdoors, the heat exchanger indoors, linked by a refrigerant line charged by a certified technician. Excluded are monoblock and hydro-split units, ground-source heat pumps, air-to-air air conditioners and hot water heat pumps. Main uses are heating replacement in homes, air-conditioned commercial buildings and long pipe runs.
Volume follows heating replacement, which reacts strongly to the German Buildings Energy Act (GEG) and the Federal Funding for Efficient Buildings (BEG). The design mix follows the EU F-Gas Regulation 2024/573: from 2027, new air-to-water units up to 12 kW face a strict refrigerant limit. Propane (R290), the substitute, is highly flammable and hard to route indoors, so monoblock units gain. Exemptions, larger outputs and cooling keep the design alive, and sales later grow again.
Which questions about the split heat pumps market does the dataset answer?
- How have split unit sales developed since Q1/2021, and when is the low point?
- How much goes into heating replacement, how much into new buildings?
- How are sales split between residential and non-residential buildings?
- How do quarterly values compare with in-house planning?
Who is the dataset for?
Split system manufacturers judge how fast to move product lines to propane monoblock designs. Suppliers of compressors and refrigerant lines plan capacity, wholesalers their stock. Contractors gauge the workload of certified installers; investors and analysts assess what refrigerant rules mean for the design.
Data basis and methodology
Figures distinguish new build from renovation in housing and non-residential buildings, plus a total. The model turns completions, permits and modernisation activity into building numbers, then applies the heat pump rate in new build, the heat pump share of heating replacements and the split share of air-to-water units, calibrating all three heat pump designs jointly. The model results were cross-checked against official statistics, industry association data and internal surveys.
Delivered as CSV and Excel files, each in German and English, with 44 quarterly values. Related datasets: Heat pump air-water (monoblock), Heat pump geothermal (brine-water / water-water), Hot water tank / buffer tank and all data on heating, ventilation, air conditioning and energy.





